JK125P, JK300P  & JK300HP

A New Generation of JK Pulsed Nd:YAG Lasers

Another innovative member of the JK family of pulsed Nd:YAG lasers is available.  The JK125P, JK300P  & JK300HP models combine higher peak powers with shorter pulse lengths for increased robustness, providing the utmost in flexibility and maximized process control for quicker yet more precise welding and fine cutting applications.

Proven production with important new field-tested enhancements

Considered a benchmark in the industry, the award-winning JK700 series of Nd:YAG lasers has been used to measure pulsed Nd:YAG laser performance.  In our new generation JK-HP and P Series lasers, GSI Group has combined over three decades experience in industrial laser manufacturing exploiting enhanced technologies for the best overall value, dependability, and cost of ownership for users of pulsed lasers.

Spanning a range of power levels, the JK-HP and P Series marks the introduction of a number of valuable features as standard across the JK product line, enhancing performance and process efficiencies while reducing integration and operating costs, training, and parts holding requirements for all users. Backed by GSI Group’s industry-leading applications expertise and worldwide support network, these reliable lasers will work harder than ever for you. Unique features our customers will enjoy include:

Performance Data

Single Lamp

Twin Lamp

Model

JK300P

JK125P

JK300HP

Max. Average Power at Laser1 (W)

300

125

300

Typical Power at Workpiece (W)

250

100

250

Max. Peak Power1 (kW)

5

2.3

9

Max. Pulse Energy 1 (J)

40

17

56

Max. Frequency

1000

Pulse Width Range (ms)

0.2 – 20

Pulse to Pulse Stability*

± 3%

Shutter Opening Time (ms)

<50

Beam Quality 2 (mm.mrad)

16

7

16

Standard Fiber Diameter (µm)

300

150

300

Standard Fiber Lengths (m)

5, 10, 15, 30

5, 10, 15

5, 10, 15, 30

Beam Delivery Options

Up to 4T or 3E or 2Tx2E combination

Max. Recollimating Lens Focal Length with 60mm square output housing (mm)  

200

With 40mm square output housing (mm)  

100

 

 

Environmental Data
Model

JK300P

JK125P

JK300HP

Cooling Water Requirements @ 15ºC input

15 l/min

4.0 US gal/min

10 l/min

2.5 US gal/min

22 l/min

5.8 US gal/min

Cooling Requirement (kW)

9.5

6

13.7

Max. Pressure Drop (bar min.)

2

Max. Inlet Pressure (bar max.)

6

Electrical Requirements

380-415 V +/-10% at 50/60 Hz

Supply Rating (kVA)

11

8

15

Max. Power Consumption

(kw)

9.5 6

13.7

Ambient Temperature (˚C)

5 – 40

Humidity

95%RH at 20oC, 50%RH at 40oC

Weight (kg)

224 222

266